Skip to main content

Radiographic study of direct anterior approach hip arthroplasty: a 10–15 year follow-up of Chinese patients

Abstract

Background

Controversy remains over whether different surgical approaches exert an impact on the component positioning in total hip arthroplasty. We conducted a retrospective study to reveal the long-term position of prostheses in the first group of patients in China who underwent direct anterior hip arthroplasty.

Methods

Collected were data from 350 patients who underwent direct anterior hip arthroplasty between 2008 and 2013, including demographic information, imaging data, Harris hip scores, and surgical complications. Variables, measured radiographically or by CT, included hip offset, leg length discrepancy, component position, and stability within one week after surgery and at the last follow-up. The data were subjected to statistical analysis by using paired t-tests and Pearson chi-square tests.

Results

Data were harvested by follow-up and self-reported questionnaires. The postoperative follow-up lasted for 13.1 years on average (minimum, 10 years; maximum, 15 years), and the overall survival rate of hip prostheses was 96.3%. The mean Harris score at the final follow-up was 91.8 points. After excluding patients with significant preoperative hip deformities, the incidence of postoperative limb inequality (> 5 mm) was 4.9% at the last follow-up, and the incidence of hip offset discrepancy (> 5 mm) was 14.6%. The overall proportion of the acetabular components located in the Lewinnek safe zone was 77.7%, whereas the proportion of femoral prostheses in the safe zone (< 3° inclination) was 94.0%. Based on the revised data and the last follow-up imaging, the total proportion of acetabular and femoral prostheses with a radiolucence of > 2 mm was 5.1%.

Conclusion

Direct anterior approach hip arthroplasty could achieve excellent component positioning and long-term prosthesis survival in patients without severe hip deformities.

Introduction

Over the past decades, direct anterior hip arthroplasty has been recognized as a minimally invasive technique performed through the muscle interval and clinically achieved outstanding results [1,2,3]. Though many related reports have been published, long-term follow-up results of direct anterior hip arthroplasty are relatively limited compared to other techniques, such as surgeries via posterolateral or anterolateral approaches. In China, surgeons incrementally employed this minimally invasive hip replacement technique since 2008. However, it was not until approximately 2015 that more medical institutions began performing direct anterior approach hip arthroplasty. Given the excellent clinical results achieved in developed countries, the use of direct anterior hip arthroplasty has been rapidly on the rise in China. Nonetheless, according to statistical data from the Orthopedics Branch of the Chinese Medical Association, as of 2020, only roughly 8.3% of joint surgeons in China used this approach [4], which is far lower than the rates in developed countries, such as the United States [5].

Multiple factors contributed to this low application rate, including a steep learning curve [6, 7], doubts about the superiority of the new technologies (since traditional surgeries are good enough), and especially concerns about the accuracy of the prosthesis position. Some joint surgeons are concerned about whether the difficulty associated with the direct anterior approach can lead to poor placement of the prosthesis, leading to a series of surgical complications [8, 9]. However, controversy remains over whether direct anterior hip arthroplasty can attain a better hip prosthesis position than other techniques, and whether it can maintain a good prosthesis position on a long-term basis [10,11,12,13]. Our institute is one of the earliest in China to introduce the direct anterior approach hip arthroplasty and has been performing the procedure for over 15 years. In this study, we retrospectively looked at the component positioning and reviewed the long-term results of direct anterior hip arthroplasty based on imaging data from follow-ups spanning 10–15 years.

Materials and methods

Patients

This retrospective study was approved by the institutional ethics committee (No. 2023416). Informed consent was obtained from all subjects included in the study. A total of 495 cases of unilateral direct anterior hip arthroplasty performed at our hospital from January 2008 to December 2013 were retrospectively included, with 31 cases excluded due to loss of follow-up and 48 cases removed due to incomplete follow-up data. Sixty-six cases were also eliminated for being diagnosed as having type III and type IV hip dysplasia, infectious hip arthritis, ankylosing hip, obvious anatomical deformities, and leg length discrepancies before surgery. A total of 350 patients who underwent direct anterior hip arthroplasty were included in this study. They included 174 cases of aseptic necrosis of the femoral head, 85 cases of type I or II dysplasia and borderline dysplasia of the hip joint with osteoarthritis, 48 cases of femoral neck fractures, 23 cases of hip osteoarthritis, and 20 cases of rheumatoid arthritis. The longest follow-up period was 15 years, and the shortest lasted 10 years, with an average of 13.1 years. All patients were implanted with uncemented prostheses, with 117 patients using Stryker’s Accolade II femoral stem and Trident acetabular cup (Stryker, Mahwah, NJ, USA) and 233 receiving Zimmer’s M/L taper femoral stem and Trilogy or TM acetabular cup (Zimmer, Warsaw, IN, USA). Two senior doctors performed the direct anterior hip arthroplasty in all 350 patients. Additional patient data are presented in Table 1.

Table 1 Characteristics of patients

Surgical technique

The patient was in a supine position and under general anesthesia. Taking the ASIS as a marker, a longitudinal incision of approximately 8 cm long was made along the longitudinal axis of the femur laterally toward the knee joint, starting about 2 cm outside and 2 cm distal to the ASIS. The fascia of the tensor fasciae latae was cut longitudinally and the muscle fibers of the tensor fasciae latae were separated from the medial muscle fascia by fingers and pulled to the outside. After careful separation and electrocoagulation of the lateral femoral circumflex vessels, the deep fascia tissue was opened to expose the fat layer in front of the hip joint. The joint capsule was cut open and two blunt retractors were used to encircle the femoral neck for osteotomy and then the femoral head was removed. The acetabulum was exposed, and the prosthesis was implanted under fluoroscopic control. After the proper release of the posterolateral capsule on the femoral side, we adducted, externally rotated, extended the affected limb, and inserted a retractor from behind the greater trochanter to lift the proximal femur. Upon preparation of the femur, a suitable prosthesis was implanted. After fluoroscopic examination and testing of limb length and joint stability, the fascia of the tensor fasciae latae and skin incision were sutured continuously.

Design

Based on postoperative X-ray films (Figs. 1, 2, 3 and 4) at one week and the last follow-up, acetabular component inclination, femoral stem alignment on the coronal and sagittal planes, bilateral hip joint offset, and length of both lower limbs were measured independently by two researchers. The radiolucence of all prostheses was also radiographically evaluated. Alignment of the femoral prosthesis on the coronal and sagittal planes was measured in terms of the angle subtended by the axis of the prosthesis and the axis of the proximal femoral cavity on X-ray. CT data of 143 patients were available, and their acetabular anteversion was directly measured. For the other 207 patients without CT data, the acetabular anteversion was measured by X-ray and converted by using Widmer’s method. While taking a plain film of the pelvis in the supine position, the radial bulb tube was tilted 10° from the ground perpendicular to the head, and both lower limbs were rotated 15° inward. Full-length films of both lower limbs were digitally used to synthesize images in three segments. The postoperative offset of the hip joint on the surgical side and the lengths of both lower limbs were compared, with the non-surgical side serving as a control. Lewinnek criteria define the acetabular component safe zone as an abduction angle of 40° ± 10° and an anteversion angle of 15° ± 10°. In this study, we defined the femoral component safe zone as an angle of ≤ 3° in both the coronal and sagittal planes. A difference of < 5 mm in the absolute length between the two lower limbs was taken as essentially equal in length. A deviation of < 5 mm between the operated and healthy sides was considered a return to the normal offset. During the follow-up period, the presence of a continuous 2 mm or more of radiolucence or subsidence around the prosthesis was seen as evidence of loosening.

Fig. 1
figure 1

Schematic diagram of hip offset measurement on the operated and healthy sides. The line segments “ab” and “cd” represent the offsets on both sides, respectively

Fig. 2
figure 2

Schematic diagram for measuring the length of both lower limbs. The distance from the center of the femoral head to the highest point of the center of talus

Fig. 3
figure 3

Widmer’s method (Anteversion = 48.05 × ab / ae – 0.3) measures the anteversion of the acetabulum on X-rays. “α” and “β” represent the abduction angle of the acetabulum and the eversion angle of the femoral stem, respectively. “X” is the longitudinal axis of the femoral stem, and “Y” is the longitudinal axis of the proximal femoral cavity

Fig. 4
figure 4

Line segments a and b represent the axes of the femoral prosthesis and the proximal femoral cavity, and the angle between them represents the alignment of the prosthesis on the sagittal plane

Statistical analysis

Mean and standard deviation were used to express continuous variables. ICC (Interclass Correlation Coefficient) was utilized to evaluate the consistency of measurement results of the same researcher and between different researchers. Changes in the acetabular anteversion and inclination angle between one week after surgery and the last follow-up were compared using a paired sample t-test for statistical analysis. The comparison between the proportion of the acetabular safe zone, offset, leg length discrepancy, and proportion of femoral component inversion was made by employing the Pearson Chi-square test. SPSS 26.0 was used for statistical analysis, and statistical significance was set at P < 0.05.

Results

Sixteen patients in this group developed severe complications, of which 13 underwent revision surgery for dislocations (n = 7), aseptic loosening (n = 3), infections (n = 2), and periprosthetic fracture (n = 1). The overall survival rate of patients with hip prostheses was 96.3% (Fig. 5). Two cases of postoperative dislocation were treated with manual reduction and conservative treatment, whereas one case of periprosthetic fracture was treated conservatively, and healing was achieved. Data such as acetabular anteversion, inclination angle, hip offset, and femoral component orientation were obtained by measurements on plain pelvic films, femoral anteroposterior and lateral view films, full-length films of both lower limbs and hip CT scan images within one week after surgery and at the last follow-up (or revision), as shown in Tables 2 and 3.

Fig. 5
figure 5

The overall survival rate of 350 cases of direct anterior approach hip arthroplasty in this group (SPSS 26.0, Kaplan–Meier analysis)

Table 2 Analysis of imaging data of acetabular prosthesis
Table 3 Analysis of imaging data of femoral prosthesis

The radiographic results of this group showed that the proportion of acetabular and femoral implants located within the safe zone was excellent, being 79.4% and nearly 90%, respectively, and this proportion remained highly consistent at follow-up after an average of 13 years. Moreover, over 80% of cases had returned to normal hip offset (difference of < 5 mm), and the proportion of bilateral lower limbs that were basically equal in length (difference of < 5 mm) was as high as 94%. Although 10 cases of acetabular prostheses and 8 femoral prostheses showed radiolucent lines (> 2 mm) during follow-up, only three of them eventually developed symptoms and required revision surgery.

Discussion

Regardless of the surgical approach used, prosthesis position is very important for hip arthroplasty. It plays a crucial role in maintaining the stability of an artificial joint in the early stages, whereas in the long term, it is related to the survival of the component [14]. Simultaneously, restoring the normal rotation center and offset of the hip, as well as the length of both lower limbs, is crucial for restoring hip function and maintaining long-term limb mobility [15]. There exists still controversy regarding whether the direct anterior approach can achieve better postoperative prosthetic position and long-term prosthetic survival [16,17,18].

Although the “absolute safety” of Lewinnek’s safe zone has been questioned [19], a large amount of clinical practice has shown that it still serves as a standard for determining the position of acetabular implants after hip arthroplasty. In cases where there is no significant deformity of the joint before surgery, or there is no fusion in the spine [20], the Lewinnek safe zone remains the most commonly used evaluation system [21]. Previously, there has been significant controversy regarding whether the direct anterior approach can achieve a better acetabular position than other commonly used surgical approaches [22,23,24]. Through a multicenter prospective study, Gromov et al. found that the direct anterior approach had the highest proportion of acetabular prosthesis positions in the safe zone and the lowest variability in acetabular anteversion and inclination angle when compared to three other surgical approaches. Therefore, they believed that the direct anterior approach could accomplish a more stable and superior acetabular position [22]. However, Maeda and Goyal et al. found no difference in the component position between the direct anterior approach and other surgical approaches [18, 25]. Some authors have warned that a direct anterior approach may increase the anteversion angle of acetabular implants, posing the risk of anterior dislocation [10]. However, this scenario may be related to the experience of the surgeon or the learning curve of the technique, which can theoretically be resolved by experience accumulation or application of other navigation tools [26, 27]. Our follow-up data revealed that although approximately 20% of the acetabular prostheses were not within the safe zone, this result was still significantly lower than the level reported in a large population of patients undergoing posterior approach [28], with an overall postoperative dislocation rate of 2% and a long-term survival rate of 96.3%. This demonstrates that the direct anterior approach can achieve excellent prosthesis positioning and long-term survival. In addition, the restoration of hip offset is crucial for maintaining good abductor function and joint stability. In this group, 13%–14% had postoperative offset differences of > 5 mm from the normal side, which is similar to the results reported by other studies [29, 30]. Although it does not cause postoperative joint instability or dislocation, whether this difference in offset can cause postoperative gait and functional abnormalities remains controversial, and further research is warranted.

It is generally believed that the proportion of femur-related complications after direct anterior approach surgery may be higher than that for other surgical approaches [31]. Technically, exposure and operation of the femoral side through the direct anterior approach is relatively difficult and prone to intraoperative femoral perforation, prosthesis inversion, and femoral fracture. The probability of such complications was higher as compared to other approaches. However, this is clearly related to the early learning curve, as confirmed by Nairn’s report [6]. Studies have also reported that the direct anterior approach is more prone to early loosening of the prosthesis and sagittal malpostion [8, 32]. According to our follow-up results, although the incidence of malposition of the femoral component stood somewhere between 6%–12%, the proportion of periprosthetic fractures and radiolucent occurring 10 years after surgery was approximately 2.3%, which is significantly lower than that reported by other authors [33] and did not increase the revision rate. Through appropriate management, such as posterior lateral capsule release and piriformis tendon or external rotator tendon release, as well as the use of traction beds, the exposure of the proximal femur can be improved, and the risk of complications can be lowered. An over 10-year postoperative follow-up in our series showed that direct anterior hip arthroplasty could achieve good long-term stability and high survival rates of femoral prostheses. The proportion of postoperative leg-length discrepancies was also relatively low in this group. According to these data, the proportion of length discrepancy exceeding 5 mm was approximately 5%, which is significantly lower than that reported in the literature [34].

This study was subject to some limitations. Firstly, cases of severe anatomical lesions of the hip joint were excluded. Therefore, this study could not conclude that a direct anterior approach can also achieve a high long-term survival rate in patients with severe hip deformity. Another limitation was the deviation in image measurement and calculation. Though researchers in our group separately measured and analyzed the imaging data of these cases, some measurements were based on X-rays, whereas others were based on CT scans, which might result in inconsistencies in the measured angles. This may have led to differences between the results of this study and the findings reported by other studies.

Conclusions

This study reported the imaging follow-up results of direct anterior hip arthroplasty in a Chinese population over a period time spanning 10–15 years. These results indicated that the direct anterior approach could achieve an excellent prosthesis position and long-term survival in patients without severe hip deformities. In the current context, where the usage rate in China is not very high, this approach has shown promise of being further promoted and more extensively employed.

Availability of data and materials

The datasets used and analyzed in the current study are available from the corresponding author on reasonable request. All data generated or analyzed during this study are included in this published article and its supplementary information files.

References

  1. Darwich A, Pankert K, Ottersbach A, Betsch M, Gravius S, Bdeir M. 5-year clinical and radiographic results of the direct anterior approach for total hip arthroplasty using a collared cementless femoral short-stem prosthesis. J Clin Med. 2022;11:346. https://doi.org/10.3390/jcm11020346.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  2. Debi R, Slamowicz E, Cohen O, Elbaz A, Lubovsky O, Lakstein D, Tan Z, Atoun E. Acetabular cup orientation and postoperative leg length discrepancy in patients undergoing elective total hip arthroplasty via a direct anterior and anterolateral approaches. BMC Musculoskelet Disord. 2018;19(1):188. https://doi.org/10.1186/s12891-018-2097-4.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Flevas DA, Tsantes AG, Mavrogenis AF. Direct anterior approach total hip arthroplasty revisited. JBJS Rev. 2020;8(4):e0144. https://doi.org/10.2106/JBJS.RVW.19.00144.

    Article  PubMed  Google Scholar 

  4. Kong N, Tian R, Cao L, Zhou Y, Wang K, Yang P. Current occupational perspective of total hip joint surgeons in China: a survey of members of the Chinese orthopedic association. Orthop Surg. 2022;14(9):2265–75. https://doi.org/10.1111/os.13405.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Patel NN, Shah JA, Erens GA. Current trends in clinical practice for the direct anterior approach total hip arthroplasty. J Arthroplasty. 2019;34:1987–93. https://doi.org/10.1016/j.arth.2019.04.025.

    Article  PubMed  Google Scholar 

  6. Nairn L, Gyemi L, Gouveia K, Ekhtiari S, Khanna V. The learning curve for the direct anterior total hip arthroplasty: a systematic review. Int Orthop. 2021;45(8):1971–82. https://doi.org/10.1007/s00264-021-04986-7.

    Article  PubMed  Google Scholar 

  7. Foissey C, Fauvernier M, Fary C, Servien E, Lustig S, Batailler C. Total hip arthroplasty performed by direct anterior approach - does experience influence the learning curve? SICOT-J. 2020;6:15. https://doi.org/10.1051/sicotj/2020015.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Abe H, Sakai T, Takao M, Nishii T, Nakamura N, Sugano N. Difference in stem alignment between the direct anterior approach and the posterolateral approach in total hip arthroplasty. J Arthroplasty. 2015;30(10):1761–6. https://doi.org/10.1016/j.arth.2015.04.026.

    Article  PubMed  Google Scholar 

  9. Nishihara S, Hayashida K. Comparison between freehand technique and computed tomography-based navigation in acetabular cup placement through direct anterior approach for total hip arthroplasty. Arch Orthop Trauma Surg. 2022;142(2):323–9. https://doi.org/10.1007/s00402-021-03920-1.

    Article  PubMed  Google Scholar 

  10. Chen AF, Chen CL, Low S, Lin WM, Chinnakkannu K, Orozco FR, Ong AC, Post ZD. Higher acetabular anteversion in direct anterior total hip arthroplasty: a retrospective case-control study. HSS J. 2016;12(3):240–4. https://doi.org/10.1007/s11420-016-9488-6.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. Luger M, Hochgatterer R, Klotz MC, Allerstorfer J, Gotterbarm T, Schauer B. A single-surgeon experience in reconstruction of femoro-acetabular offset and implant positioning in direct anterior approach and anterolateral MIS approach with a curved short stem. Arch Orthop Trauma Surg. 2022;142(5):871–8. https://doi.org/10.1007/s00402-021-03977-y.

    Article  PubMed  Google Scholar 

  12. Kunze KN, Huddleston HP, Romero J, Chiu YF, Jerabek SA, McLawhorn AS. Accuracy and precision of acetabular component position does not differ between the anterior and posterior approaches to total hip arthroplasty with robotic assistance: a matched-pair analysis. Arthroplast Today. 2022;18:68–75. https://doi.org/10.1016/j.artd.2022.08.004.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Ji W, Stewart N. Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach. Int Orthop. 2016;40(1):21–7. https://doi.org/10.1007/s00264-015-2803-x.

    Article  PubMed  Google Scholar 

  14. Seagrave KG, Troelsen A, Malchau H, Husted H, Gromov K. Acetabular cup position and risk of dislocation in primary total hip arthroplasty. Acta Orthop. 2017;88(1):10–7. https://doi.org/10.1080/17453674.2016.1251255.

    Article  PubMed  Google Scholar 

  15. Benson JR, Govindarajan M, Muir JM, Lamb IR, Sculco PK. Surgical approach and reaming depth influence the direction and magnitude of acetabular center of rotation changes during total hip arthroplasty. Arthroplasty today. 2020;6(3):414–21. https://doi.org/10.1016/j.artd.2020.04.003.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Busch A, Wegner A, Wassenaar D, Brandenburger D, Haversath M, Jäger M. SuperPath® vs. direct anterior approach: A retrospective comparison between two minimally invasive approaches in total hip arthroplasty. SuperPath® vs. direkteranteriorerZugang: Ein retrospektiverVergleich der Implantatpositionierungzwischenzwei minimal-invasivenVerfahren in der Hüftendoprothetik. Orthopadie (Heidelberg, Germany). 2022;51(12):986–95. https://doi.org/10.1007/s00132-022-04310-0.

    Article  PubMed  Google Scholar 

  17. Martin JR, Masonis JL, Mason JB. Anatomic total hip component position is more reproducible with the direct anterior approach using intraoperative fluoroscopy. Arthroplast Today. 2020;6(4):777–83. https://doi.org/10.1016/j.artd.2020.07.026.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Maeda Y, Sugano N, Nakamura N, Hamawaki M. The accuracy of a mechanical cup alignment guide in Total Hip Arthroplasty (THA) through direct anterior and posterior approaches measured with CT-based navigation. J Arthroplasty. 2015;30(9):1561–4. https://doi.org/10.1016/j.arth.2015.04.011.

    Article  PubMed  Google Scholar 

  19. Tang H, Zhao Y, Wang S, Ma Z, Li Y, Shi H, Zhou Y. Conversion of the sagittal functional safe zone to the coronal plane using a mathematical algorithm: the reason for failure of the Lewinnek safe zone. J Bone Joint Surg Am. 2022;104:641–8. https://doi.org/10.2106/JBJS.21.00840.

    Article  PubMed  Google Scholar 

  20. Wang Y, Wang R, Gong S, Han L, Gong T, Yi Y, Feng Y, Wang G, Xu W. A comparison of radiological and clinical outcomes between robotic-assisted and conventional total hip arthroplasty: a meta-analysis. Int J Med Robot. 2023;19(1):e2463. https://doi.org/10.1002/rcs.2463.

    Article  PubMed  Google Scholar 

  21. Burapachaisri A, Elbuluk A, Abotsi E, Pierrepont J, Jerabek SA, Buckland AJ, Vigdorchik JM. Lewinnek safe zone references are frequently misquoted. Arthroplasty today. 2020;6(4):945–53. https://doi.org/10.1016/j.artd.2020.09.011.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Gromov K, Greene ME, Huddleston JI, Emerson R, Gebuhr P, Malchau H, Troelsen A. Acetabular dysplasia and surgical approaches other than direct anterior increases risk for malpositioning of the acetabular component in total hip arthroplasty. J Arthroplasty. 2016;31(4):835–41. https://doi.org/10.1016/j.arth.2015.10.045.

    Article  PubMed  Google Scholar 

  23. Hamilton WG, Parks NL, Huynh C. Comparison of cup alignment, jump distance, and complications in consecutive series of anterior approach and posterior approach total hip arthroplasty. J Arthroplasty. 2015;30(11):1959–62. https://doi.org/10.1016/j.arth.2015.05.022.

    Article  PubMed  Google Scholar 

  24. Jackson JB, Martin JR, Christal A, Masonis JL, Springer BD, Mason JB. The direct anterior approach total hip arthroplasty reliably achieves “Safe Zones” for combined anteversion. Arthroplasty today. 2020;6(4):651–4. https://doi.org/10.1016/j.artd.2020.07.023.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Goyal T, Choudhury AK, Paul S, Gupta T, Das L. Acetabular and femoral component positioning using direct anterior approach versus posterior approach in total hip arthroplasty. Indian J Orthop. 2021;55(5):1215–24. https://doi.org/10.1007/s43465-020-00343-9.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Foissey C, Batailler C, Coulomb R, Giebaly DE, Coulin B, Lustig S, Kouyoumdjian P. Image-based robotic-assisted total hip arthroplasty through direct anterior approach allows a better orientation of the acetabular cup and a better restitution of the centre of rotation than a conventional procedure. Int Orthop. 2023;47(3):691–9. https://doi.org/10.1007/s00264-022-05624-6.

    Article  PubMed  Google Scholar 

  27. Thorne T, Nishioka S, Andrews S, Mathews K, Nakasone C. Component placement accuracy of two digital intraoperative fluoroscopy supplementation systems in direct anterior total hip arthroplasty. Arch Orthop Trauma Surg. 2020;142(6):1283–8. https://doi.org/10.1007/s00402-021-04008-6.

    Article  Google Scholar 

  28. Danoff JR, Bobman JT, Cunn G, Murtaugh T, Gorroochurn P, Geller JA, Macaulay W. Redefining the acetabular component safe zone for posterior approach total hip arthroplasty. J Arthroplasty. 2016;31(2):506–11. https://doi.org/10.1016/j.arth.2015.09.010.

    Article  PubMed  Google Scholar 

  29. Bjørdal F, Bjørgul K. The role of femoral offset and abductor lever arm in total hip arthroplasty. J Orthop Traumatol. 2015;16(4):325–30. https://doi.org/10.1007/s10195-015-0358-7.

    Article  PubMed  PubMed Central  Google Scholar 

  30. Mahmood SS, Mukka SS, Crnalic S, Wretenberg P, Sayed-Noor AS. Association between changes in global femoral offset after total hip arthroplasty and function, quality of life, and abductor muscle strength. A prospective cohort study of 222 patients. Acta Orthop. 2016;87(1):36–41. https://doi.org/10.3109/17453674.2015.1091955.

    Article  PubMed  Google Scholar 

  31. Kinney MC, Ho H, Hamilton WG. AAHKS best podium presentation research award: femoral perforation during direct anterior approach total hip arthroplasty: incidence, cohort characteristics, and management. J Arthroplasty. 2022;37(8S):S721–6. https://doi.org/10.1016/j.arth.2022.02.110.

    Article  PubMed  Google Scholar 

  32. Angerame MR, Fehring TK, Masonis JL, Mason JB, Odum SM, Springer BD. Early failure of primary total hip arthroplasty: is surgical approach a risk factor? J Arthroplasty. 2018;33(6):1780–5. https://doi.org/10.1016/j.arth.2018.01.014.

    Article  PubMed  Google Scholar 

  33. Meneghini RM, Elston AS, Chen AF, Kheir MM, Fehring TK, Springer BD. Direct anterior approach: risk factor for early femoral failure of cementless total hip arthroplasty: a multicenter study. J Bone Joint Surg Am. 2017;99(2):99–105. https://doi.org/10.2106/JBJS.16.00060.

    Article  PubMed  Google Scholar 

  34. Kishimoto Y, Suda H, Kishi T, Takahashi T. A low-volume surgeon is an independent risk factor for leg length discrepancy after primary total hip arthroplasty: a case-control study. Int Orthop. 2020;44(3):445–51. https://doi.org/10.1007/s00264-019-04435-6.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This work was supported by the Shanghai General Hospital Research Project (grant number: CCTR-2022ZD04, CTCCR-2021C11), and National Natural Science Foundation Project (grant number: 82172411).

Author information

Authors and Affiliations

Authors

Contributions

W.S. and P. L. designed the study and wrote the original draft; X.X. and Y.L. collected and analyzed the data; Y.L. was also involved in the investigation and supervision; J.M. and L.Z. were responsible for the project administration; L.Z. reviewed and edited the manuscript. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Jinzhong Ma or Libo Zhu.

Ethics declarations

Ethics approval and consent to participate

This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of Shanghai General Hospital (No. 2023416). Informed consent was obtained from all individual participants included in the study.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sang, W., Lai, P., Xu, X. et al. Radiographic study of direct anterior approach hip arthroplasty: a 10–15 year follow-up of Chinese patients. Arthroplasty 6, 25 (2024). https://doi.org/10.1186/s42836-024-00249-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s42836-024-00249-z

Keywords